JXF Outdoor Marshalling Kiosk | Substation Field Termination & Control Interface
Boerstn Electric Co.,Ltd is one of the toppest Marshalling Kiosks in China.During these years of exporting , Boerstn Electric Co.,Ltd now has rich experience in the worldwide markets
Share This Product:
  • Introductory Part

1. Introduction

Ruggedized Outdoor Marshalling Kiosks for High-Voltage Substations

Engineered as the critical field termination point between HV switchyard equipment and your control room. The JXF series provides weatherproof signal marshalling, local monitoring, and auxiliary power distribution in a fully enclosed, welded steel cabinet built for harsh outdoor environments.

✅ IP65 Weatherproof Rating | ✅ IEC60439 Compliant | ✅ -40°C to +55°C Operating Range | ✅ 690V / 630A Rated


2. Product Overview: Why This Kiosk?

The JXF Marshalling Kiosk is not a standard distribution panel—it is a purpose-built substation interface enclosure. Designed explicitly for outdoor installation on concrete pads within high-voltage switchyards, it serves three critical functions:

Field Cable Termination Hub: Organizes and terminates control, protection, and instrumentation cables from transformers, circuit breakers, and isolators before routing to the control room.

Local Operation & Monitoring Station: Provides front-panel ammeters, voltmeters, selector switches, and status indicators for safe on-site verification without entering the main control building.

Auxiliary Power Distribution: Delivers rated 3-phase AC power (50/60Hz, up to 690V, 630A) for motor starting, lighting, and heater circuits directly at the equipment location.

Built with a fully welded profile assembly and corrosion-resistant coating, the JXF withstands UV exposure, rain, dust, temperature extremes, and mechanical impact—ensuring decades of reliable service in unattended outdoor locations.

3. Key Specifications Table


Parameter

Specification

Application

Outdoor HV Substation Switchyard / Field Termination

System Voltage

3-Phase AC 50/60Hz, Max 690V

Rated Current

Up to 630A

Enclosure Protection

IP65 (Weatherproof, Dust-Tight, Jet-Proof)

Construction

Fully Welded Steel Profile Assembly

Corrosion Protection

ISO 12944 C4/C5-M Industrial/Marine Grade Coating

Ambient Temperature

-40°C to +55°C

Internal Climate Control

Space Heater + Thermostat (Anti-Condensation)

Mounting

Free-Standing on Reinforced Concrete Pad

Front Panel Components

Ammeter, Voltmeter, Signal Lamps, Selector Switches, Push Buttons

Standards Compliance

IEC60439, IEC 62271 (HV Interface), Utility Grid Codes

Wiring Options

Customizable Terminal Blocks, Surge Protection, Grounding Bus


4. Critical Service Conditions (Outdoor Validated)

⚠️ Designed Exclusively for Outdoor Substation Environments

Temperature Range: Operates reliably from -40°C to +55°C, accounting for direct solar heating that can add 10–15°C above ambient air temperature. Internal space heater prevents condensation during cold/humid conditions.

Humidity & Condensation: Rated for 100% RH with condensation. Sealed gaskets and internal heaters prevent moisture ingress and tracking/flashover risks.

Installation Altitude: Suitable up to 2,000m above sea level.

Environmental Exposure: Resistant to UV radiation, industrial pollution, salt mist (coastal sites), wind loading, and wildlife intrusion. Rodent/bird-proof cable entry glands included.

Mechanical Stability: Must be installed on a reinforced concrete foundation with anchor bolts. Designed to withstand wind loads per local utility standards. Not suitable for wall mounting.

Vibration & Impact: Welded construction resists vibration from nearby HV equipment and accidental impact. No violent shock exposure permitted.



5. Why Choose the JXF for Your Substation?

Eliminate Indoor-Rated Enclosures Outdoors: Avoid costly failures from water ingress, UV degradation, and condensation. The JXF is validated for direct outdoor exposure.

Reduce Control Room Cable Clutter: Terminate field cables locally, minimizing long runs back to the control building and improving signal integrity for protection relays.

Enable Safe Local Operations: Front-panel instruments and controls allow technicians to verify circuit status and perform switching operations at the equipment location, reducing response time during faults.

Utility-Grade Compliance: Meets IEC60439 and relevant grid operator specifications for outdoor LV switchgear and marshalling equipment, ensuring acceptance during technical evaluation.

Customizable Wiring Architecture: Flexible terminal block layouts, surge protection options, and grounding configurations adapt to complex substation designs without redesigning the enclosure.


Feedback form contact with us
Related Product
145~252KV Hybrid Gas Insulated Switchgear (HGIS)
145~252KV Hybrid Gas Insulated Switchgear (HGIS)
Overview 1. 1 ZHW-145 Hybrid Gas Insulated Switchgear (hereinafter referred to as HGIS) belongs to three-phase AC ...
LW36-72.5~145KV  Outdoor SF6 Circuit Breaker
LW36-72.5~145KV Outdoor SF6 Circuit Breaker
Summary LW Series self-energy SF6 Circuit Breaker is a three-pole/single-pole AC 50Hz/60Hz outdoor high voltage power transmission...
LW36-72.5~252KV Outdoor SF6 Circuit Breaker
LW36-72.5~252KV Outdoor SF6 Circuit Breaker
Summary LW Series self-energy SF6 Circuit Breaker is a three-pole/single-pole AC 50Hz/60Hz outdoor high voltage power transmission...
LW30-72.5~252KV Outdoor SF6 Dead Tank Circuit Breaker
LW30-72.5~252KV Outdoor SF6 Dead Tank Circuit Breaker
Dead tank type SF6 Gas Circuit- Breaker 72.5kV up to 252KV, 25kA~63kA, 1250A~4000A for Outdoor Three phase/Si...
Product Catalog